EO/IR Imaging for Beginners: How Much IR Power Reaches a Pixel?

How Much Infrared Power Reaches a Detector Pixel? A beginner’s guide to modeling a resolved, Lambertian thermal source using blackbody/graybody emission, hand calculations, and Non-Sequential Ansys OpticStudio Zemax

Introduction

Electro-optical and infrared (EO/IR) imaging combines radiometry, optical design, detector physics, and image quality. For someone new to the field, understanding how those pieces connect can be challenging. This article is the first part of a three-part introductory EO/IR imaging series using analytical calculations and Ansys Zemax OpticStudio.

The series will cover:

  1. Thermal Radiometry — How Much IR Power Reaches a Pixel? Hand Calculations vs. Zemax
  2. Resolution — Can the Camera Resolve the Target? Diffraction, Pixel Size, MTF, and Zemax
  3. Detection — Can the Detector Actually See It? Photon Flux, Noise, NEP, and SNR

In Part 1, we focus on a passive thermal-imaging problem: how much infrared power reaches a single detector pixel? Unlike reflective imaging, the target itself emits infrared radiation based on its temperature and emissivity.

We will analyze a resolved 320 K graybody source in the 8–10 µm band and work through the radiometry required to predict the power collected by one detector pixel. We will then compare that analytical result with the detector power calculated in Zemax OpticStudio.

EO IR Imaging 1 intro problem

How much radiant power from the 320 K scene reaches one 10 um x 10 um detector pixel?

  1. Calculate the source emittance.

For a blackbody, the spectral radiant emittance is given by Planck’s law:

EO IR imaging 2 equation

We can build a simple spreadsheet in excel to do the calculations. We only care about the wavelength band between 8 to 10 um.

EO IR imaging 3 blackbody and source emittance line graph
EO IR imaging 4 blackbody and source emittance table
EO IR imaging 5 blackbody and source emittance table 2

Using numerical integration multiplied by the emissivity of 0.98, the source emittance is calculated as

M = 0.008339 W/cm2

This is the total radiant power emitted by one square centimeter of the source into the hemisphere above it, considering only the 8-10 um wavelength band.

  1. Convert emittance to radiance

Next in our EO/IR imaging study, we need to determine how that emitted power is distributed directionally. We are assuming the source is Lambertian.

For a Lambertian source, there is a convenient form emittance equal to pi multiplied by radiance:

M = πL

Where:

EO IR imaging 6 radiant emittance equations
EO IR imaging 7 radiant emittance terms and units

Using the source emittance, we can easily calculate the radiance to be:

L = 0.0026545 W/(cm2sr)

Emittance tells us how much total power leaves a unit area of the source.

Radiance tells us how much of that power travels in a particular direction, per unit solid angle.

At this point we have characterized the thermal source:

EO IR Imaging 7.5 characterization of thermal source
  1. How much of the target does one pixel see?

Now that we understand the source, we need to determine the physical area on the target that corresponds to one detector pixel.

EO IR imaging 8 detector pixel equation

It’s a simple relation of similar triangles:

EO IR imaging 9 relation of similar triangles equations

So, each pixel subtends an angular width of approximately 100 micro-radians in object space. Therefore, one pixel (10 μm ×10 μm) corresponds to a

20 cm × 20 cm

patch of the target.

Asrc = 400 cm2

One 10 μm pixel sees a 20 cm × 20 cm target area at 2 km.

  1. Calculate the intensity of that piece of the source:

From Step 2 in our EO/IR imaging study, we calculated the source radiance and from Step 3 we calculated the Area of the source that 1 pixel sees. We can now calculate the Intensity associated with that resolved source area as

EO IR Imaging 10 intensity equation

In the 8-10 μm band, we now have these quantities of the source and light entering the system.

EO IR Imaging 10.5 quantities of source and light equations
  1. What solid angle does the aperture subtend?

Next in our EO/IR imaging study, we need to determine how much of the source’s emitted intensity is intercepted by the entrance aperture.

For a circular aperture the Area is calculated as

EO IR Imaging 11 circular aperture area

For a small aperture viewed from a large distance, the solid angle is approximately

EO IR Imaging 12 solid angle small aperture viewed from large distance

From the target’s perspective, the 5 cm entrance aperture occupies an extremely small cone of directions. That is the fraction of angular space into which the source must radiate energy to enter the imaging system.

We can calculate the Power entering the aperture.

  1. Calculate the power entering the imaging system:

The Power intercepted by the aperture is

P = IΩ = (1.0618)(4.909*10^-10) = 0.521 nW.

For a perfect, lossless F/2 imaging system places approximately 0.52 nW of 8-10 um optical power onto this 10 um pixel when viewing a 320 K, emissivity = 0.98 resolved source.

The really interesting result in our EO/IR imaging study:

If we start with Power and substitute Intensity with a Lambertian source we can arrive at a very powerful observation.

EO IR Imaging 13 lambertarian source equations

Notice what is missing: R.

Range has disappeared. For a uniform resolved extended source, increasing the range means the aperture subtends a smaller solid angle:

EO IR Imaging 14 equation

but the physical area of the target seen by one pixel increases as

EO IR Imaging 15 equation

The two effects cancel.

Now we can make it even simpler with F# (the cone of the beam)!

EO IR Imaging 16 equations
  1. Confirm with Zemax NSC Detector:

EO IR Imaging 17 Zemax NSC Detector simulation results

Summary

  1. Source Emittance
    What it tells us: How much 8–10 µm infrared power the 320 K source emits per unit area.
    Why it matters: This defines how strong the thermal source is.
  2. Convert Emittance to Radiance
    What it tells us: How much of that emitted power travels in a given direction.
    Why it matters: The camera only receives radiation traveling toward it.
  3. How Much of the Target Does One Pixel See?
    What it tells us: The physical area on the target that maps to one detector pixel.
    Why it matters: We need to know which part of the target contributes to that pixel.
  4. Calculate the Intensity of That Target Area
    What it tells us: How much infrared power that specific target patch emits per unit solid angle.
    Why it matters: This gives the directional power coming from the part of the target seen by one pixel.
  5. Solid Angle Subtended by the Aperture
    What it tells us: How large the camera aperture appears from the target.
    Why it matters: Only the radiation traveling into this small angular region can enter the camera.
  6. Power Entering the Imaging System
    What it tells us: How much infrared power from that target patch actually enters the camera.
    Why it matters: This is the final radiometric result for one pixel and can be compared directly with the Zemax result.

EO/IR Imaging in Conclusion

In Part 1, we followed the radiometric chain from a 320 K graybody source to the power collected by a single detector pixel. Starting with source emittance, we converted to radiance, determined the portion of the target seen by one pixel, calculated the radiant intensity of that target area, found the solid angle of the entrance aperture, and finally predicted the power entering the imaging system.

The result was approximately:

P ≈ 0.521 nW

for one pixel in the 8–10 µm band. The equivalent Zemax OpticStudio model produced essentially the same detector power, giving us confidence that the analytical radiometry and the simulation are describing the same physics.

Coming Next in the EO/IR Imaging for Beginners Series

In Part 2, we’ll build on these radiometric calculations by exploring resolution, diffraction, pixel sampling, and modulation transfer function (MTF). We’ll also walk through the thermal imaging setup in Ansys Zemax OpticStudio Non-Sequential Mode to connect the analytical results with a working optical model.

Advance Your EO/IR Imaging Capabilities with SimuTech Group

Accurate EO/IR imaging simulation requires an understanding of how thermal radiation, optical design, and detector performance work together. Whether you’re developing an infrared camera, evaluating imaging system performance, or validating analytical calculations, SimuTech Group’s optical simulation experts can help you apply Ansys Zemax OpticStudio to your engineering challenges.

Explore our Optical Simulation Consulting Services to learn how we can support your optical system design and validation efforts.

Charles Taylor

Charles Taylor
Staff Engineer – Optics, SimuTech Group

Charles J. Taylor is an Optical Engineer at SimuTech Group specializing in optical design and simulation using Ansys Zemax OpticStudio. He holds a Master of Optical Sciences from the University of Arizona, where his research examined diffraction and alignment sensitivity in segmented telescope systems. His technical expertise includes ray tracing, physical optics propagation, polarization, and laser system analysis, with a focus on helping engineers develop, evaluate, and validate optical designs.